EasyManua.ls Logo

COBAN GROUP TK103A - Overspeed Alarm; ACC Working Alarm; Vibration Alarm (TK103 B Optional )

COBAN GROUP TK103A
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
6.10.5 Overspeed alarm
6.10.5.1 Set up: Send SMS speed+password+space+80 to the unit(suppose
the speed is 80km/h),and it will reply “speed OK!”. When the target moves
exceeding 80km/h.the unit will send SMS speed+Geo-info” to the central
number.
6.10.5.2 Cancel: Send SMS speed+password+space+0 to deactivate the
overspeed alarm.
Remark: It is recommended that the speed alarm is set at not less than
30km/h.For below that rate; it may cause the excursion of the GPS signal
influenced by clouds etc.
6.10.6 ACC working alarm
6.10.6.1 This function is disabled as default. To active this functions, send
"ACC+password+Space+1" to tracker, it will reply "ACC,CONFIG OK". And
tracker will send "ACC on+latitude & longitude" to central number when detect
ignition action, that means the vehicle has been started.
6.10.6.2 Send "ACC+password+Space+0" to disabled this function, tracker
will reply "ACC,CONFIG OK".
6.10.7 Vibration alarm (TK103B optional )
Send SMS “vibrate+password+space+0 to deactivate this function.
Send SMS vibrate+password+space+1-3 to set up vibrate level from 1 to 3
(1 is strongest level, 3 is lowest level)