Chapter 4: Using the Terminal Control Unit
40 Configuration
Configuring SSA button type
There are two types of SSA buttons. You can distinguish between the two
types by the color of the test button:
Standard activation:
Covert alert buttons are latched red buttons.
Test button is green.
Instant activation:
Covert alert buttons are non-latched red buttons.
Test button is yellow.
To configure the SSA button type in the connected SAILOR 3027, connect
a computer and access the SAILOR 3027 settings as described in Using
commands on page 35. Then enter the command for configuration of SSA
buttons.
Configuring SSA message repeat rate
When an SSA button is pushed, an SSA message is sent with regular
intervals to the SSA message recipients. The default interval is 30 minutes,
but you can change the interval to anything between 20 and 60 minutes.
To change the interval (repeat rate), do as follows:
1. Connect a computer and access the SAILOR 3027 settings as described
in Using commands on page 35.
2. Enter the command for configuration of the repeat rate:
Setting up software controlled power management
By default, when the system is powered on, the Terminal Control Unit and
the connected mini-C Terminal are always on. You can change this
Note
Software controlled power management is only available for
SAILOR 6140 and SAILOR 6150 (see the next section).
For SAILOR 6110, 6120 and 6130 you can only use a switch
connected to X1 to switch between on and standby. For location
of X1 see Connector overview on page 14.