I.GENERAL SPECIFICATIONS
A. GENERAL
CH=14 CHANNELS WITHIN 462-467 MHZ
B.RECEIVER
UNIT
1. SENSITIVITY
FOR 12 DB SINAD uV 0.25
FOR CALL SIG.DETECTION uV 0.2
2. MAX. AUDIO OUTPUT @10% THD MW 100
3. MAX.S/N RATIO @ 1mV RF INPUT DB 45
4. SQUELCH
a) SENS. uV 0.2
b) ATTACK TIME mS 120
c) CLOSING TIME mS 200
5. AUDIO FREQUENCY RESP.
@ 300 HZ DB -6
@ 3000 HZ DB -6
6. SIGNAL DISPLACEMENT BW +/-KHZ 5
7. ADJACENT CH.REJECTION DB 55
8. INTERMODULATION REJECTION DB 55
9. SPURIOUS RESPONSE REJECTION DB 65