Emphasizes user safety and patient well-being, urging careful reading of safety notes.
Outlines manufacturer's responsibility for product safety, reliability, and performance when used as instructed.
Lists critical safety instructions for operating the equipment safely and preventing injury.
Details the impact of improper use, assembly, or modifications on warranty claims.
Explains magnetic field effects and operating modes for patients with cardiac pacemakers.
Information on the control unit's suitability for explosive atmospheres and its equipment classification.
Approval status of motor and foot control for use in specific zones and note on low-speed operation.
Guidelines for mains cable connection, power failure handling, and system failure notifications.
Details on intermittent operating mode, coolant use, and irrigation tubing sterility.
Explains how rapid deceleration can lead to torque overload due to stored rotational energy.
Step-by-step guide for safely removing all components from the packaging.
Details the specific items included in each Osscora surgical set model (91051, 91052, 91053).
Identifies and describes the controls and indicators on the front panel of the control unit.
Details the ports, power switch, and fuse holder located on the rear panel.
Instructions for motor maintenance, preventing turning during transmission, and conducting a test run.
General procedure for connecting the mains cable, foot control, motor, and stand.
Explains the function of each button (Green, Grey, Orange, Yellow) on the foot control unit.
Guide to selecting programs (1-3) and operating the pump via the foot control.
Instructions for switching motor direction and understanding the signals for reverse operation.
Procedure to change the foot control's motor speed setting from variable to ON/OFF.
Table detailing factory default rpm, torque, motor direction, and pump settings for programs P1, P2, P3.
Step-by-step guide to restore the control unit to its original factory settings.
How to select programs (P1-P3) and understand the information shown on the display.
Method for increasing or decreasing motor speed using program buttons P1 and P2.
Procedure for setting the motor torque in 5-Ncm increments for program P3.
How to modify the coolant flow rate using program button P2.
A table listing common error codes, their descriptions, and recommended corrective actions.
Guidance on actions to take when errors persist after initial troubleshooting attempts.
Overview of country-specific guidelines and initial cleaning steps for the motor.
Instructions for pre-disinfection and manual cleaning of the control unit and foot control.
Specific instructions for cleaning, disinfecting, and handling the motor and its cable.
Approved steam sterilisation methods (Class B/S) and guidelines for storing the motor and accessories.
Diagram and list identifying all parts of the Osscora contra-angle handpiece.
Important safety notes, especially for Dermatome use, and initial steps before first use.
Step-by-step instructions for securely connecting and disconnecting the handpiece from the motor.
How to insert, change, and safely operate rotary instruments within the handpiece.
Procedure for inserting and securing rotary instruments that use a hexagon chucking system.
Guidelines for performing a test run after using the handpiece and reporting issues.
Detailed instructions for manual or automatic cleaning, disinfection, and lubrication of the handpiece.
Step-by-step process for taking apart the Osscora contra-angle handpiece.
Instructions for rinsing disassembled handpiece parts with demineralised water and drying.
Procedures for cleaning external coolant tubes and spray nozzles, and handling blockages.
Method for disinfecting the handpiece using surface disinfectants and final sterilization requirements.
Recommendations for cleaning and disinfecting the handpiece using a thermo washer disinfector.
Step-by-step guide for putting the Osscora contra-angle handpiece back together.
Guidance on daily oil service, recommended lubricants, and lubrication cycles.
Procedure for running the handpiece after lubrication to remove excess oil and ensure proper function.
Approved steam sterilisation procedures and best practices for storing the handpiece.
Lists and illustrates accessories such as sterilisation cassette, irrigation tubing, motor, and handpiece.
Details the required regular servicing and safety checks for the surgical set and accessories.
Information on motor servicing intervals, procedures for repairs, and returning equipment.
Provides key technical data including voltage, current, power, torque, and dimensions.
Details the equipment's protective class, appliance type, and adherence to relevant safety standards.
Specifies temperature/humidity limits for operation and storage, and outlines the product warranty.