Configuration
Copyright © 2013 Coda Octopus Products Ltd
14
F175 MOTION Sensor - Trimble SPS361/SPS461 Integration
5. Click the OK button to save your configuration to the Trimble SPS361/SPS461
WARNING: At this point the settings will only be used until you restart the Trimble
SPS361/SPS461 receiver. Follow the next steps to make them more permanent.
6. In the Web Interface go to Receiver Configuration on the left hand menu and select the
sub-menu Application Files. Here use the Store Current File option to store the current
application file receiver settings to the non-volatile RAM of the receiver. You are prompted
to name the file. We recommend that you use a name that clearly defines what the
application file is to be used for.
7. The next time you restart the Trimble SPS361/SPS461 receiver go to Receiver Configuration
menu and select the sub-menu Application Files. Use the option Start Now and use the
application file you have saved in the step before. Then click OK to start the application file
and use the settings until the next restart.
NOTE: If you want to load a specific application file by default when the Trimble
SPS361/SPS461 is started, please consult the Trimble SPS361/SPS461 manual on how
to configure the receiver to use specific settings when it is turned on.