PROBLEM PROBABLE CAUSE REMEDY
NO SIREN OUTPUT. A. SHORTED S PEAKER OR SPEAKER
W IRES. SIREN IN OVER CURRENT
PROTECTION MODE.
A. CHECK
CONNECTIONS.
10A FUSE BLOW S. A. AMPLIFIER POW ER W IRES REVERSED
POLARITY.
A. CHECK POLARITY.
NO OUTPUT FROM
SPEAKER, TONES
HEARD INSIDE AMP.
MODULE.
A. SPEAKER NOT CONNECTED/OPEN OR
SHORTED SPEAKER W IRING.
B. DEFECTIVE SPEAKER (NOTE: SHORTED
SPEAKER OR SPEAKER W IRING W ILL
CAUSE SIREN TO SHUTDOW N.
A. CHECK SPEAKER
W IRING.
B. DISCONNECT
SPEAKER. LISTEN AT
SIREN FOR TONES,
REPLACE SPEAKER.
SIREN TONES VOLUME
TOO LOW /GARBLED
A. LOW VOLTAGE TO SIREN AMPLIFIER.
B. HIGH RESISTANCE IN W IRING/
DEFECTIVE SPEAKER.
A. CHECK W IRING FOR
BAD CONNECTIONS/
CHECK VEHICLE
CHARGING SYSTEM.
B. CHECK SPEAKER
W IRING/REPLACE
SPEAKER.
HIGH RATE OF
SPEAKER FAILURE.
A. HIGH VOLTAGE TO SIREN.
B. 58 W ATT SPEAKER CONNECTED TO 100
W ATT TAP. 58 W ATT NOT ALLOW ED.
A. CHECK VEHICLE
CHARGING SYSTEM.
B. USE CORRECT
SPEAKER.
SIREN CONTINUES
UNTIL TONE RAMPS
DOW N AFTER MANUAL
BUTTON IS RELE ASED.
NORMAL OPERATION.
INTERCLEAR W ILL NOT
POW ER AUXILIARY
DEVICES.
A. THERE IS A SHORT IN THE WIRING, OR
THE LOAD IS GREATER THAN 1 A.
A. CHECK FOR
SHORTS.
P.A. VOLUME LOW OR
NO P.A. AT ALL.
VOLUME CONTROL
FULLY CLOCKW ISE.
A. DEFECTIVE MICROPHONE.
B. MAXIMUM P.A. VOLUME TRIMMER
MISADJUSTED. SEE SET-UP AND
ADJUSTMENT SECTION.
A. REPLACE
MICROPHONE.
B. REFER TO SET-UP
AND ADJUSTMENT
SECTION.
RRB VOLUME LOW , OR
NO RRB AT A LL.
VOLUME CONTROL
FULLY CLOCKW ISE.
A. MAXIMUM RADIO REBROADCAST
TRIMMER MIS-ADJUSTED.
B. RRB W IRES NOT CONNECTED TO TW O-
W AY RADIO EXTERNAL SPEAKER.
A. REFER TO SET-UP
AND ADJUSTMENT
SECTION.
B. CHECK RRB
CONNECTIONS.
SIREN SOUNDS BY
ITSELF.
A. REMOTE SW ITCH (HORN RING) W IRING
TO REMOVE INPUT SHORTING TO POSITIVE
OR TO GROUND (EARTH).
A. CHECK W IRING FOR
ANY SHORTING.
P.A. OPERATES BUT
SIREN W ILL NOT RUN.
A. VEHICLE IN PARK; THE PARK KILL
FEATURE MUTES SIREN W HILE VEHICLE IS
IN PART OR NEUTRAL.
B. RRB SW ITCH IS ON.
A. PUT VEHICLE IN
GEAR.
B. TURN RRB SW ITCH
OFF (LEFT).
SIREN RUNS PROPERLY
BUT SHUTS DOW N
W HILE RUNNING. THEN
STARTS RUNNING
AGAIN AFTER A FEW
MINUTES.
A. VEHICLE CIRCUIT BREAKERS ARE
OVERHEATING OR ARE NOT FUNCTIONING
PROPERLY.
A. USE A BREAKER
W ITH 1.25x. THE
AMPERAGE RATING
FOR THE WATTAGE
BEING USED.
SIREN TROUBLESHOOTING GUIDE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Code 3 R 1200RT-P and is the answer not in the manual?

Code 3 R 1200RT-P Specifications

General IconGeneral
BrandCode 3
ModelR 1200RT-P
CategoryAutomobile Accessories
LanguageEnglish

Related product manuals