6
PROBLEM PROBABLE CAUSE REMEDY
SIDE FACING LIGHT NOT
W ORKING W ITH FRONT
OR REAR GROUP AS
EXPECTED.
A. DIP SW ITCH IN THE W RONG POSITION
OR NOT FULLY IN POSITION.
A. CHECK DIP
SW ITCHES.
LIGHTHEAD DOES NOT
ACTIVATE
A. NO POW ER TO UNIT.
B. DAMAGED OR SHORTED CABLING.
C. DEFECTIVE LIGHTHEAD.
D. GROUND NOT SECURE.
A. CHECK W IRING FOR
LOOSE CONNECTIONS.
B. CHECK CABLES FOR
DAMAGE.
C. REPLACE
LIGHTEHAD MODULE.
D. CHECK GROUND
W IRES. TIGHTEN IF
NECESSARY.
FLASHER TROUBLESHOOTING GUIDE
NOTE: LIGHTHEADS OPERATE ON 12V DC SYSTEMS. THE LIGHTHEAD CAN BE ATTACHED TO
A 12V POW ER SOURCE TO DETERMINE IF THE LIGHTHEAD IS W ORKING PROPERLY. THE
LIGHT HEAD W ILL STEADY BURN (TURN ON, BUT NOT FLASH) IF IT IS W ORKING CORRECTLY.