Code 3 XCEL Series - User Manual

Code 3 XCEL Series
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
Contents:
Introduction............................................................................2
Congurable Features.........................................................2-3
Standard Features................................................................3-5
Dip Switch Features................................................................6
Unpacking & Pre-installation..................................................7
Installation & Mounting............................................................7
Amplier Power Distribution.................................................8
Troubleshooting..................................................................9
Siren Wiring Diagram.............................................................10
Siren Specications..............................................................11
Lighting Specications........................................................11
Siren Control Head - Exploded View.......................................12
Siren Control Head - Parts List................................................13
Notes................................................................................14-15
Warranty................................................................................16
SIREN
PATENTED. See https://secure.code3pse.com/patents/
WARNING
Sirens produce loud sounds that may damage hearing
Wear hearing protection when testing
Use siren only for emergency response
Roll up windows when siren is operating
Avoid exposure to the siren sound outside of vehicle
Read all instruction and warnings before installing and using.
INSTALLER: This manual must be delivered to the end user of this equipment.
XCEL SERIES
IMPORTANT:
TM

Other manuals for Code 3 XCEL Series

Questions and Answers

  • P
    Pamela BallardSep 4, 2025
    What causes high speaker failure rate in Code 3 Security System?
    • J
      julie14Sep 4, 2025
      If you're experiencing a high rate of speaker failure with your Code 3 Security System, it could be caused by: * High voltage to the siren. Check the vehicle charging system. * Using an incorrect speaker. A 58-watt speaker connected to a 100-watt tap is not allowed; use the correct speaker.
  • A
    amymerrittSep 18, 2025
    Why does Code 3 Security System RRB shut off after extended use?
    • J
      Jacqueline AllenSep 18, 2025
      This is normal. The RRB shuts off after an extended period when the equipment starts to overheat. This is to avoid damage to the components in the amplifier. Allow the amplifier a few minutes to cool down.
  • J
    Jason MckeeSep 16, 2025
    Why does Code 3 Security System PA only function for 30 seconds?
    • C
      clarkangelSep 16, 2025
      This is normal behavior for the Code 3 Security System. The PA function turns off after 30 seconds to prevent a stuck microphone. To continue broadcasting, release the PTT button and press it again for another 30 seconds of broadcast ability.
  • J
    John DavisSep 14, 2025
    What causes the LT light to be off when the 3 level switch is active on Code 3 Security System?
    • S
      Sean Medina IVSep 15, 2025
      If the 3 level switch is active in any level but the LT light is off on your Code 3 Security System, it indicates that one or more of the 3 level fuses have blown in the amplifier. Replace the fuse(s) in the amplifier.
  • B
    Brian RobertsSep 12, 2025
    Why does my Code 3 Security System siren shut down and restart intermittently?
    • R
      reedconnieSep 13, 2025
      If your Code 3 Security System siren runs properly but shuts down intermittently, it may be due to vehicle circuit breakers that are not rated properly, are overheating, or are not functioning correctly. Refer to the specifications section on page 11 and use a breaker rated at 1.25 times the amperage of the expected load current.
  • J
    Jaclyn ReedSep 12, 2025
    Why is LT light off when auxiliary button is active on Code 3 Security System?
    • J
      Jonathan HillSep 12, 2025
      If the active auxiliary push button lights up but the LT light is off on your Code 3 Security System, one or more of the auxiliary fuses in the amplifier may have blown. Replace the fuse(s) in the amplifier.
  • C
    Corey ThompsonSep 9, 2025
    Why are Code 3 Security System siren tones too low or garbled?
    • B
      buckcodySep 9, 2025
      If the siren tones volume on your Code 3 Security System is too low or sounds garbled, it could be due to: * Low voltage to the siren amplifier. Check the wiring for bad connections and inspect the vehicle charging system. * High resistance in the wiring or a defective speaker. Check the speaker(s) wiring and consider replacing the speaker(s).
  • P
    Paul MuellerSep 7, 2025
    What to do if Code 3 Security System has no speaker output but tones are heard inside?
    • S
      Sara HernandezSep 8, 2025
      If you hear tones inside the amplifier module of your Code 3 Security System, but there's no output from the speaker and the SP indicator light is off, it could be due to: * The speaker not being connected or an open circuit in the speaker wiring. Check the speaker wiring. * Defective speakers. Replace the speaker(s).
  • B
    bellmicheleSep 5, 2025
    How to troubleshoot low or no RRB volume on Code 3 Security System?
    • M
      matthew50Sep 5, 2025
      If the RRB (Radio Rebroadcast) volume is low or absent on your Code 3 Security System, the following could be the cause: * The radio rebroadcast volume may need to be increased. Refer to the setup and adjustment section. * The RRB wires might not be connected to the two-way radio's external speaker. Check the RRB connections.
  • B
    Bryan MoodyAug 21, 2025
    What to do if Code 3 Automobile Accessories siren has no output?
    • R
      robinsonkennethAug 21, 2025
      If your Code 3 Automobile Accessories siren has no output, it could be due to several reasons. First, check if the park kill is activated and shift the vehicle out of park. Second, verify the SirenLock level and select the proper one. Lastly, inspect the speaker and speaker wires for shorts, as the siren might be in over-current protection mode. Check all connections to ensure they are properly secured.

Summary

XCEL SERIES SIREN

General Safety Warnings

Sirens produce loud sounds that may damage hearing; wear hearing protection.

Standard Features

3-Level Switch Operation

Explains the function of the 3-level switch for changing warning modes.

Auxiliary Button Configuration

Details on configuring auxiliary buttons, park kill, horn ring, and alerts.

MANUAL Push-Button Operation

Describes the Manual Wail tone and Hit-N-Go mode.

AIR HORN Push-Button Operation

Details the Air Horn tone and its interaction with other features.

Auxiliary A-F Push-Buttons

Explains the function and control of six auxiliary push-buttons.

Hit-N-Go Feature

Explains the Hit-N-Go feature activated by horn ring or manual button.

Scroll Feature

Describes how the horn ring scrolls through siren tones.

Configurable Features (L6 Models)

Configurable Features (Non-Light Control)

Installation and Mounting

Amplifier Power Distribution

Troubleshooting

XCEL Siren Wiring Diagram

Siren Specifications

Lighting Specifications

Code 3 XCEL Series Specifications

General IconGeneral
BrandCode 3
ModelXCEL Series
CategorySecurity System
LanguageEnglish

Related product manuals