IP1500/2500
User Guide
ConguringDiagnostics
Diagnostic Settings
TheIP1500/2500speakerphonediagnosticsettingsareconguredby:
SelectingDiagnostic Settings in the Code Blue Conguration.
ClicktheEnablecheckbox.
InputtheSNMP ServerIPaddress
andSNMP Server Portnumberto
monitortheIP1500/2500withan
SNMPmanagementsoftwareorwith
CodeBlue’sToolVoxGateway,with
UnitProgramming&Diagnostic(UPD)Software.
PoEPowerFailure:PoEpoweristhesolepowersourceandifaninterruptioninserviceisexpe-
rienced,noTrapwillbesentduetolossofPoEenergy.ThePoEswitchshouldalertyoutoPoE
switchstate.
Others – (Tests)
Microphonetestingisdisabledbydefault,andenablingwillshowanumberofreoccurringtest
routines.Themicrophoneissupportedbythespeaker’sabilitytogeneratetonesattheschedule
intervals.
Thetestconsistsofbeepsfromthespeaker,whichwillbereceivedbythemicrophone.
The maximum number of beeps: 10 beeps
Oncethemicrophonedetectsthebeeps,thetestiscompleteuntilthenextscheduledtestis
present.
The beep tone volume choices are soft, loud, or soft to loud.
Beeptonevolumesettingshouldbesettoanticipateambientnoiselevelatthetimeofthe
test.
Thetestschedulechoicesare:
Every15minutes
Hourly
Daily
Weekly
Testingondemand:Whenmicrophonespeakertestingisenabled,theadministratormayselectto
Run Test whileloggedintotheIP1500/2500.Theresultsofthetestwillonlybepresentinafailed
SNMPtrap,whichwouldappearintheSNMPserverlogsorUPDDiagnosticReportslogs.TheMIB
valueisCODEBLUE-MIB::micSpeakerFailure.