4/14/2016
D014465 CR1400 CR1000 CR2300 CR2600 CR3600 CR44X5 CR8000 CR900FD CR6000 CR5000 T500 Client Version ICD
Page 61 of 106
© 2013-2016 The Code Corporation
12393 South Gateway Park Place Suite 600, Draper, UT 84020
(801) 495-2200
FAX (801) 495-0280
Reg
Setting Name
Default (Hex)
Comment
E5
Trigger 3 Confirmation
Time (ms)
0
Valid Range: 0 to 7FFFFFFF Milliseconds
The trigger input must be asserted for this amount of time
before the trigger event is generated. Setting this value > 0
makes it easier to select combinations of triggers (e.g. trigger
3, which is trigger 1 & 2 asserted together).
E6
Trigger 4 Confirmation
Time (ms)
0
Valid Range: 0 to 7FFFFFFF Milliseconds
The trigger input must be asserted for this amount of time
before the trigger event is generated. Setting this value > 0
makes it easier to select combinations of triggers (e.g. trigger
3, which is trigger 1 & 2 asserted together).
E7
Trigger 5 Confirmation
Time (ms)
0
Valid Range: 0 to 7FFFFFFF Milliseconds
The trigger input must be asserted for this amount of time
before the trigger event is generated. Setting this value > 0
makes it easier to select combinations of triggers (e.g. trigger
3, which is trigger 1 & 2 asserted together).
E8
Trigger 6 Confirmation
Time (ms)
0
Valid Range: 0 to 7FFFFFFF Milliseconds
The trigger input must be asserted for this amount of time
before the trigger event is generated. Setting this value > 0
makes it easier to select combinations of triggers (e.g. trigger
3, which is trigger 1 & 2 asserted together).
E9
Trigger 7 Confirmation
Time (ms)
0
Valid Range: 0 to 7FFFFFFF Milliseconds
The trigger input must be asserted for this amount of time
before the trigger event is generated. Setting this value > 0
makes it easier to select combinations of triggers (e.g. trigger
3, which is trigger 1 & 2 asserted together).
EB
Maximum Reader To
Host Packet Data Size
(bytes)
4000
(#16384)
Valid Range: 1 to 4000 (#16384) Bytes
EC
Host
Acknowledgement
Time Limit Multiplier
(ms)
F
(#15)
Valid Range: 0 to 7FFFFFFF Milliseconds
When Expect Acknowledgement From Host (register 42) is
nonzero, the Reader will wait up to Host Acknowledgement
Time Limit (register 37) + dataSize * Host Acknowledgement
Time Limit Multiplier (register EC) milliseconds to receive an
acknowledgement from the Host.
ED
Prefix Decode Result
With AIM Symbology
Identifiers
0
0: Don’t prefix with AIM identifier
1: Prefix decode result with ISO/IEC standard 15424/AIM
symbology identifier
Keywords: #AIMId