Maintenance
WARNING Prior to any maintenance or inspection procedures, ensure that the
MicroClean 2 is powered down and the power source is disconnected.
Ensure that the air supply is closed, bled o, and the air supply hose is
disconnected from the MicroClean 2.
Daily
y Inspect the trough area for any dirt or debris.
y Inspect the air and blast hoses for damage such as cuts, kinks, or deformation.
y Inspect power connections for cuts, or worn surfaces. Repair or replace as necessary.
y Inspect ttings on the applicator and MicroClean 2 for loose or improper connections
and correct as necessary.
y Inspect applicator blast cable for wear or improper connections and correct as
necessary.
y Inspect the applicator for any damage or loose parts and correct as necessary.
y Inspect the shaver blades for cracks or damage.
Weekly
y Inspect the inside of the trough for dirt and inspect slicer blades for cracks, gouges, or
broken surfaces.
y Verify the nozzle airow exit end is not deformed or burred.
Every 250 Hours or 12 Months
y Replace the shaver blades or sooner in the event damage can be seen to one or more
of the blades.
y Replace the air lter.
Troubleshooting
Use Cold Jet CONNECT
TM
to troubleshoot possible errors on the machine. If the issue cannot
be resolved, contact Cold Jet at (see Contact Information page 58). Warnings do not shut
down the MicroClean 2. Warnings will display in two states. Yellow which means that an item
is nearing a point that attention must be given and red which means that an item needs
immediate attention.
Error’s generally will cause the MicroClean 2 to go in to the shut down mode. An error code will
display in the status screen (page 35 Status Screen item 11). An error indicates a fault shutting
down the MicroClean 2 to prevent damage to the system or a error serious in nature has
occurred in which case you will need to contact Cold Jet Customer Service. The MicroClean 2, in
error shut down mode, will continue powered up but will not operate.