Copyright - refer to title page
INSTALLATION GUIDE FOR RX-7W22, II2
7.4
APPENDIX D: TROUBLESHOOTING QUICK GUIDE
Alarm list:
Figure 33: Alarm list
Troubleshooting:
Environment temperature shall be lower than 140degF (60degC)
Hardware failure, RMA the equipment
Hardware failure, RMA the equipment
1.
Handling RF connectors when RF power is ON may damage LNA
2.
High power injection to DT/MT port may damage LNA
Fix any other existing alarms first, then reset PA (see next page)
If alarm still exists, RMA the equipment
Other critical alarm causes the equipment shutdown
Follow instructions to fix other alarms first
Check input power to DT port, the power shall be lower than -30dBm
1.
Avoid other inference
2.
Put attenuator between antenna and PS BDA, if donor signal is high
Antenna Malfunction
Dry contact alarm
Signal Booster Failure
Dry contact alarm
DT composite input power lower than -80dBm will trigger the alarm
1.
Donor antenna/passive system failure
2.
Wrong channel frequency setting
3.
Site is not commissioned yet
VSWR
Service antenna/passive system failure