USAGE
WARNING: First of all read the Safety War-
nings and then this Specic Manual
.
> PUT INTO SERVICE
See g.
A
> STARTING UP
See g.
B
> HIGH PRESSURE LANCE
See g.
D
> DETERGENT SUCTION
See g.
E
> HIGH PRESSURE HOSE
See g.
F
> WATER SUPPLY
Water supply collection
WARNING (symbol):
machine not suitable
for connection to the potable water mains.
The cleaner can only be connected to the
water mains if the water mains is separated by
a backow preventer.
Make sure that the hose is at least Ø 13mm-1/2
inch and that it is reinforced.
WARNING: Water that has own through
backow preventers is considered to be non-
potable
.
IMPORTANT: Only clean or ltered water should
be used for intake. The delivery of the water
intake tap should be equal to the double of the
maximum pump range.
Place the cleaner as close to the water supply
system as possible.
Failure to comply with the above conditions
causes serious mechanical damage to the
pump and the loss of warranty cover.
Water supply from the potable water mains
KRM 1100 / RM 1100
Classic
KRM 1100 / RM 1100
Extra
Fuse 16 A
Minimum inlet water temperature 5 °C - 41 °F
Minimum inlet water ow 900 l/h - 15 l/min - 172 US gph
Maximum inlet water pressure 1 MPa - 10 bar - 145 psi
Minimum inlet water pressure 0,1 MPa - 1 bar - 14,5 psi
Recoil of cleaner gun 10 N
Sound pressure level - Uncertainty (*) 81 dB(A) - 0,7 dB(A)
Sound power level 96 dB(A)
Operator arm vibrations - Uncertainty (*) 1,5 m/s² - 0,5 m/ s²
Lenght x width x height 310 x 280 x 650 mm - 12,2 x 11 x 25,6 in
Detergent tank capacity -- 0,7 l - 0,18 US gal
Detergent bottle capacity
0,3 l - 0,08 US gal --
(*) Measurements taken in compliance with EN 60335-2-79
All features and technical specications are only indications. The Manufacturer reserves the right to modify the appliance as it
deems necessary.
For other technical data, refer to the identication plate on the machine (see data interpretation on page 15 of this
manual).