6.2 STORAGE
Wind up the high-pressure pipe (7) or (24) carefully and avoid bending it.
Wind up the electric power supply cable (14) and hook it to its support (11).
Put the water cleaner in a clean and dry place making sure that the electric power supply cable
and the high-pressure pipe are not damaged.
WARNING
The water cleaner is not frost proof.
In order to prevent the formation of ice inside the water cleaner in cold areas, it is possible to
make the high pressure cleaner take up a motor vehicle grade anti freeze before starting the
Switch off” procedures. Contact a Skilled Technician before attempting this as the pumped
liquid could damage the seals in the high-pressure pump.
If it is not possible to protect the high pressure cleaner in cold areas as described above, it must
be brought into a warm room for the time required to melt any ice which may have formed
inside it before attempting to start it up again.
If these instructions are not followed, the high pressure cleaner may be seriously damaged.
7 CLEANING AND MAINTENANCE
« CAUTION
Only start cleaning and maintenance once the instructions in the Switching off” section have
been completed.
It is particularly important to always disconnect the electricity supply.
To safeguard the safety of the high pressure cleaner, only use the original spare parts supplied
by the Manufacturer or those endorsed by him.
The rubber pipes, the coupling and the high-pressure lances are important for safety: only use
those endorsed by the Manufacturer.
7.1 ROUTINE MAINTENANCE
Follow the instructions in the “Switching off” section and abide by the recommendations in the
table below.
INTERVAL FOR
MAINTENANCE
ACTION
Each time used Check the supply cable, high-pressure pipe, couplings, cleaner gun, lance pipe.
Should any of these parts appear to be damaged, do not use the high pressure cleaner
and contact a Skilled Technician.
Weekly
Clean the water inlet lter (26).
Usually, it is sufcient to pass the lter under running water or in a jet of compressed air to
clean it. In more difcult cases, use a lime scale remover or replace the lter. Contact an
authorised service centre for the purchase of a new lter.
Monthly
Clean the nozzle.
For cleaning, it is generally enough to pass the supplied pin (19) inside the nozzle hole. In case
you do not obtain any appreciable result, apply to an authorised service centre.
WARNING
During use, the high pressure cleaner should not be too noisy and large amounts of water or
oil should not drip from underneath it.
In this event, a Skilled Technician should test the appliance.