EasyManua.ls Logo

Comet KSM - Special Maintenance; 8 Dismantling and Disposal

Comet KSM
108 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
32
33
7.2 SPECIAL MAINTENANCE
« CAUTION
Only Skilled Technicians are authorised to carry out special maintenance.
Follow the instructions in the table below for special maintenance.
INTERVAL FOR MAINTENANCE ACTION
Every 50 hours Check the pump hydraulic circuit.
Check the pump xing.
Every 100 hours Replace the pump oil.
Check the pump suction/delivery valves.
Check the pump screws are tightened.
Check the pump adjustment valve.
Check the safety devices.
WARNING
The data in the table are indications.
8 DISMANTLING AND DISPOSAL
Only trained personnel are allowed to dismantle the high pressure cleaner in accordance with the
current regulations in the country where it is installed.
« CAUTION
Before disposing of the high pressure cleaner, make sure it is no longer possible to operate it,
by cutting the power supply cable for example. Make sure all its parts are inoffensive, as they
could prove to dangerous to children playing.