CTK04 ComfortNet™ Communicating Thermostat
19
I/O-CHTSTAT03 69-268807
Dehumidification Away Mode
DehumidificationAwayModeprotectsthehomewhenunoccupiedforlongperiods
oftimeduringhotandhumidweatherbymaintainingthedesiredhumidityand
temperature settings.
TostartDehumidificationAwayMode,press
Menu,thenpressDehumidificationAwayMode.
Thethermostatautomaticallyfollowssettings
thataresetbythedealerduringinstallersetup.
PressCanceltoendDehumidificationAway
Mode.
Southern Dehumidification Away Mode
Options: (ISU 9180 to 9200)
• Fan:Auto,OnorCirculate
• LowLimitTemperatureSetting:The
thermostatallowsthecoolingsystem
tolowertheindoorairtotheLowLimit
TemperatureSettingtocontrolhumidity.
• TemperatureSetting:Thetemperature
maintainedwhileDehumidificationAway
Mode is active and the desired humidity level is satisfied.
• DehumidificationSetting:ThedesiredhumiditylevelwhileDehumidification
AwayModeisactive.
Ventilation
Ventilation Control Method (ISU 10050)
ThethermostatcancontrolthefantomeeteitherASHRAEorPercentOnTime
settings.IftherequiredventilationhasnotbeenachievedforASHRAEorPercentOn
Timeduringcallsforheatandcool,thethermostatwillforcethefanon.
• ASHRAE:ThethermostatoperatesthefantomeettheASHRAE62.2
ventilationstandardbasedonCFM,numberofbedrooms,andsquarefootage
ofthehouse.ASHRAE62.2canonlybemetifthefanisrunning.Ifthefanis
offforanyreason(setuptoturnOffduringSleepperiod,turnedoffbyuser
etc.),ASHRAE62.2isnotmetduringthosetimes.
• Percent On Time:Thethermostatoperatesthefanbasedonapercentage
enteredintheinstallersetup(ISU10120).Forexample,ifPercentOnTime
issetto50%,thefanwillrunatrandomtimesduringa1hourperioduntilit
reachesa50%runtime(approximately30minutes).Options10%to100%.
To see all ventilation options, press MENU > INSTALLER OPTIONS > VIEW/EDIT CURRENT SETUP >
VENTILATION.

Other manuals for ComfortNET CTK04

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ComfortNET CTK04 and is the answer not in the manual?

ComfortNET CTK04 Specifications

General IconGeneral
Wi-FiYes
Humidity ControlYes
Temperature ControlYes
Product TypeThermostat
BrandComfortNET
ModelCTK04
TouchscreenYes
ColorWhite
CompatibilityHVAC systems
ProgrammableYes
Temperature Range45°F to 99°F

Related product manuals