INS_CNGE11FX3TX8MS[POE][HO] Rev. 11.6.17 PAGE 310
INSTRUCTION MANUAL CNGE11FX3TX8MS[POE][HO]
TECH SUPPORT: 1.888.678.9427
Configuring ERPS from the ICLI
Initial Switch Configuration
The following commands disable STP and LLDP, and they enable C-Port on Port 1 and 2 on all
switches.
#Configure port 1-2
interface GigabitEthernet 1/1-2
#set C-Port
switchport hybrid port-type c-port
switchport mode hybrid
#disable LLDP
no lldp receive
no lldp transmit
#disable Spanning Tree Protocol
no spanning-tree