EasyManuals Logo

Compac CNG User Manual

Default Icon
125 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
K-Factor Switch
Dispenser Set-up
Compac Industries Ltd.
Page 30
www.compacngv.com
To adjust the electronic pressure
reading
1. Make sure that the dispenser is idle, with the nozzle in its holster.
2. Press and release the K-Factor switch until the required pressure
reading is shown (u, uA, ub, uA2 or ub2 )
3. Enter in the new pressure.
Each press of the K-Factor switch passes you over a
digit in a setting, making the digit blink. Holding the switch down for
more than a second changes whichever digit is currently displayed. If
you want to pass over a setting without changing any digits, keep
pressing and releasing the switch.
Let the menu time out so that the value and quantity amounts are
displayed.

Table of Contents

Other manuals for Compac CNG

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Compac CNG and is the answer not in the manual?

Compac CNG Specifications

General IconGeneral
BrandCompac
ModelCNG
CategoryDispenser
LanguageEnglish

Related product manuals