K-Factor Switch
Dispenser Set-up
Compac Industries Ltd.
Page 30
www.compacngv.com
To adjust the electronic pressure
reading
1. Make sure that the dispenser is idle, with the nozzle in its holster.
2. Press and release the K-Factor switch until the required pressure
reading is shown (u, uA, ub, uA2 or ub2 )
3. Enter in the new pressure.
Each press of the K-Factor switch passes you over a
digit in a setting, making the digit blink. Holding the switch down for
more than a second changes whichever digit is currently displayed. If
you want to pass over a setting without changing any digits, keep
pressing and releasing the switch.
Let the menu time out so that the value and quantity amounts are
displayed.