Dispenser Set-up
K-Factor Switch
Compac Industries Ltd.
Page 31
www.compacngv.com
Pressure Transducer Gain (Fast Fill & Temperature Compensated Units Only)
The pressure transducer gain (GAinA, GAinb, GAinA2 and
GAinb2) is a correction factor used to ensure the pressure transducer is
correctly calibrated. Typical values for the gain are usually close to
0.4000.
GAinA and GAinA2 relate to the gains of pressure transducers one
and two (where fitted) on side A of the dispenser.
GAinb and GAinb2 relate to the gains of pressure transducers one
and two (where fitted) on side B of the dispenser.
The pressure transducer gain is set during the calibration phase and does
not require adjusting during service
To adjust the Pressure Transducer
Gain
1. Make sure that the dispenser is idle, with the nozzle in its holster.
2. Press and release the K-Factor switch until the required gain is
shown (GAinA, GAinb, GAinA2 or GAinb2 )
3. Enter in the new gain.
Each press of the K-Factor switch passes you over a
digit in a setting, making the digit blink. Holding the switch down for
more than a second changes whichever digit is currently displayed. If
you want to pass over a setting without changing any digits, keep
pressing and releasing the switch.
Let the menu time out so that the value and quantity amounts are
displayed.
Target Fill Pressure (Fast Fill & Temperature Compensated Units Only)
The target fill pressure (FPA and FPb) is the final desired vehicle fill
pressure after filling and temperature compensation. The units of
measure are in bar.
FPA is the target fill pressure of side A of the dispenser.
FPb is the target fill pressure of side B of the dispenser.
Do not set the target fill pressure so that it is above the
maximum fill pressure.
To adjust the Target Fill Pressure
1. Make sure that the dispenser is idle, with the nozzle in its holster
2. Press and release the K-Factor switch until the required target fill
pressure is displayed flow rate is displayed. ( FPA or FPb )
3. Enter the new target fill pressure.
Each press of the K-Factor switch passes you over a
digit in a setting, making the digit blink. Holding the switch down for
more than a second changes whichever digit is currently displayed.
If you want to pass over a setting without changing any digits, keep
pressing and releasing the switch.
4. Let the menu time out so that the value and quantity amounts are
displayed.