Reference Guide
A-7
Writer: Dianne Fielden Saved by: Holly Jahangiri Saved date: 07/24/97 4:39 PM
Pages: 8 Words: 1702 Template: c:\template\commercial\commapp.dot
File Name Appa.doc Part Number 308336-001
General Information
1. The cord set must be approved for the country where it will
be used.
2. The appliance coupler (that is, the connector to the device
itself, not the wall plug) must have a configuration for mating
with a EN60 320 appliance inlet (Standard Sheet C14).
3. The length of the cord set must be as follows:
❏
Minimum: 6.50 ft (2.0 m)
❏
Maximum: 9.75 ft (3.0 m)
U.S. and Canada
1. The cord set must be UL-Listed and CSA-Certified.
2. The minimum specifications for the flexible cord are:
❏
No. 18 AWG
❏
Type SJ
❏
3-conductor
3. The cord set must have a rated current capacity of at least 10 A.
4. The attachment plug must be an earth-grounding type with a
NEMA 5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V)
configuration.
Japan
1. All components of the cord set (cord, connector, and plug)
must bear a “T” mark and registration number in accordance
with the Japanese Dentori Law.
2. The minimum specifications for the flexible cord are:
❏
0.75 mm
2
conductors
❏
Type VCT or VCTF
❏
3-conductor
3. The cord set must have a minimum rated current capacity
of 7 A.
4. The attachment plug must be a two-pole, grounded type
with a Japanese Industrial Standard C8303 (15 A, 125
VAC) configuration.