Grounding Equipment
Use the following equipment to prevent static electricity damage to the equipment:
Wrist Straps are flexible straps with a minimum of 1 mega ohm +/- 10% resistance
to the ground cords. To provide proper ground, a strap must be worn snug against
the skin. On grounded mats without banana-plug connectors, connect a wrist strap
with alligator clips.
Heelstraps/Toestraps/Bootstraps can be used at standing workstations and are
compatible with most types of boots and shoes. On conductive floors or dissipative
floor mats, use them on both feet with a minimum of 1 mega ohm resistance between
operator and ground. To be effective, the conductive strips must be worn in contact
with the skin.
Top
Recommended Materials and Equipment
Other materials and equipment that are recommended for use in preventing static
electricity include:
Antistatic tape
Antistatic smocks, aprons, or sleeve protectors
Conductive bins, and other assembly or soldering aids
Conductive foam
Conductive tabletop workstations with ground cord of 1 mega ohm
of resistance
Static dissipative table or floor mats with hard tie to ground
Field service kits
Static awareness labels
Wrist straps and footwear straps providing 1 mega ohm (+/- 10%) resistance
Material handling packages
Conductive plastic bags
Conductive plastic tubes
Conductive tote boxes
Metal tote boxes
Opaque shielding bags
Transparent metallized shielding bags