Parity Check 2
Probable Cause Recommended Action
Parity error found in the I/O bus 1. Run Setup.
2. Replace the ISA board (modem).
Back to Top
Real Time Clock Error
Probable Cause Recommended Action
Real-time clock fails BIOS test Replace the system board.
Back to Top
System Battery is Dead
Probable Cause Recommended Action
RTC battery is dead 1. Replace the RTC battery.
2. Run Setup.
Back to Top
System BIOS Shadowed
Probable Cause Recommended Action
System BIOS copied to Shadow RAM Replace the system board.
Status message only; no action required.
Back to Top
System Cache Error
Probable Cause Recommended Action
RAM cache failed the BIOS test Run Setup.
Back to Top
System CMOS Checksum Bad
Probable Cause Recommended Action
CMOS is corrupted or modified incorrectly Run Setup.
Back to Top
System RAM Failed at Offset, nnn
Probable Cause Recommended Action