Compu Chlor Manual AU 11
7.2 Wiring
7.2.1 The Power Module comes with a standard 240VAC 10Amp power cable that is to
be connected to mains power. Plug the power cable into a suitable weatherproof
outlet.
7.2.2 Plug the pump power cable into the outlet on the Power Module. The pump outlet is
located on the base of the Power Module. The pump output is rated at 240VAC, 8
Amp max. Check the electrical rating marked on the pump motor. Connecting a
pump with a higher amperage rating may result in permanent damage to the Power
Module.
7.3 Installing the Power Module
7.3.1 Mount the Power Module as close to the pump and filtration system as possible.
Make sure the Cell Cable can reach the section of pipe selected for the cell. Do
not install the Power Module within 3 meters of the pool edges.
7.3.2 Fasten the supplied screws and anchors to the wall that the Power Module will be
mounted to at eye level. The screws must be positioned at a spacing of 300mm.
Once the screws are firmly and correctly in place lift the Power Module onto them,
ensuring the Power Module correctly slides down onto the screws.
7.4 Installing the Cell Module
7.4.1 Be sure the pool pump is turned off.
7.4.2 The Cell Module is to be fitted into the return line to the pool after the pump, filter
and heater (if applicable). Water flow should come from the filtration system
through the inlet closest to the Cell Cable and down through the opposite outlet.
7.4.3 Make sure that the Cell Cable reaches from the Power Module to the area where
you will be installing the Cell.
7.4.4 The Cell can be installed in either a vertical orientation, or a horizontal orientation
as shown in Figure 2. If installing in a horizontal configuration, a gas trap must be
made in the plumbing for the water sensor to operate correctly.
7.4.5 The Cell Housing will accept 50mm PVC pipe to the inside of the sockets. For a
40mm PVC plumbing configuration, use 50mm to 40mm reducers in the cell
housing sockets then connect to the 40mm pipe.
7.4.6 When gluing the PVC pipe to the Cell Housing, use plumbing Cleaner Primer to
clean and prepare the pipe ends and Housing sockets. Use plumbing Solvent
Cement glue to join the pipe ends to the Housing.