UGH025-0504 Thermolator TW Series
INSTALLATION 3-19
TW-2 CONTROL
INSTALLING THE
AUTO START
FEATURE
NOTE: All dip switch illus-
trations in this manual show
switches 7 and 8 set to ON.
If you have an Isolated
Circuit model, these switch-
es should be set to OFF.
Set dip switch 4 to the
ON position.
Close the electrical
enclosure and restore power
to the unit.
When Auto Start is enabled:
u The Auto Start indicator light flashes to indicate that the
Thermolator can start at any time. The Thermolator will
start whenever the remote switching or timing device sends
a signal to start processing.
u The Auto Start indicator light is on whenever the
Thermolator is under the control of the remote device.
To disable Auto Start:
Repeat steps 1, 2 and 7, setting dip switch 4 to the OFF posi-
tion instead of the ON position.
6
876
54
3
21
7