5.Blocking(Duress)
The CT1000 is blocked for 1 minute after 4 incorrect codes.
Indication: *
6. Manuel Reset
CT1000 can be reset to default settings manually.
Turnothevoltage,connecttheyellowandbrownwire,turnthepoweronagainandthe
readersLED’slightandthebuzzersounds.WhenonlytheyellowLEDislitandthereaderis
silent,turnothepowerandseparatetheyellowandbrownwire.
The CT1000 is now reset to default and the user codes are deleted.
7.TechnicalSpecications
Voltage: 12 VDC, 30 mA
Voltage interval: 9 - 25 VDC
Output(yellowcore): Max.500mA
Output(whitecode): Max.500mA
ExternalcontrollinggreenandredLED
Externalcontrollingbuzzer,HoldandLock
Protection rate: IP67
Color: Blackorwhite
Dimensions(HxWxD): 130x50x8mm
Thank you for using Conlan’s products.