2
The device may not work for
all
patients. If you are unable to achieve stable readings,
discontinue use.
The update period of data is less than 5 seconds, which is changeable according to different
individual pulse rate.
If some abnormal conditions appear on the screen during test process, pull out the finger and
reinsert to restore normal use.
The device has normal useful life for three years since the first electrified use.
The hanging rope attached the product is made from Non- allergy material,
if
particular group
are sensitive to the hanging rope, stop using it. In addition, pay attention to the use of the
hanging rope , do not wear
it
around the neck avoiding cause harm to the patient.
The instrument dose not have low-voltage alarm function,
it
only shows the low-voltage
please change the battery when the battery energy is used out.
W hen t he parameter is particular
ly
, The instrument dose not have alarm function . Do not use
the device
in
situations where alarms are required.
Batteries must be removed
if
the device is going to be stored for more than one month , or else
batteries may leak.
A
flexible circuit connects the two part s of the device . Do not twist or pull on the connection.
1.4
1.4
1.4
1.4 Indication
Indication
Indication
Indication
for
for
for
for
Use
Use
Use
Use
The Fingertip Pulse Oximeter is a non-invasive device intended for the spot-check of oxygen
saturation of arterial hemoglobin (SpO
2
) and the pulse rate of adult and pediatric patients
in
home
and hospital environments (including clinical use
in
internist/surgery, anesthesia, intensive care ect.).
This device is not intended for continuous monitoring.
2
2
2
2 O
O
O
O verview
verview
verview
verview
The pulse oxygen saturation is the percentage of HbO
2
in
the total
Hb
in
the blood, so-called the O
2
concentration
in
the blood. It is an important bio-parameter for the respiration . F or the purpose of
measuring the SpO
2
more easily and accurately, our company developed the Pulse Oximeter.
At
the
same time, the device can measure the pulse rate simultaneously .
The Pulse Oximeter features
in
small volume, low power consumption, convenient operation and
being portable. It is only necessary for patient to put one of his fingers into a fingertip photoelectric
sensor for diagnosis, and a display screen will directly show measured value of Hemoglobin
Saturation.
2
2
2
2 .1
.1
.1
.1 Classification:
Classification:
Classification:
Classification:
Class II b , MDD93/42/EEC IX Rule 10
2
2
2
2 .2
.2
.2
.2 Features
Features
Features
Features
Operation of the product is simple and convenient.
The product is small
in
volume, light
in
weight ( total weight is about 50 g including batteries)
and convenient
in
carrying.
Power consumption of the product is low and the two originally equipped AAA batteries can be
operated continuously for 24 hours.
The product will automatically be powered off when no signal is
in
the product within 5

Questions and Answers: