I
CMS-50F User Instructions
By: Contec Medical Systems
Distributed By:

Other manuals for Contec CMS-50f

Questions and Answers:

Contec CMS-50f Specifications

General IconGeneral
Device TypePulse Oximeter
ModelCMS-50F
Measurement ParametersSpO2, Pulse Rate
Pulse Rate Measurement Range30-250 bpm
Pulse Rate Accuracy±2 bpm or ±2%
Display TypeOLED
Power ConsumptionLess than 30mA
SpO2 Measurement Range0% - 100%
SpO2 Accuracy±2% (70%-99%)
Resolution1% for SpO2, 1 bpm for Pulse Rate
Battery Type2 x AAA batteries
Battery LifeUp to 30 hours
Data StorageNo
Weight50g (including batteries)
Automatic shutdownYes

Summary

Safety Guidelines

Safe Operation Procedures

Details safe operational practices and periodic inspection requirements for user safety.

Critical Warnings

Highlights essential safety alerts, including environmental hazards and patient sensitivities.

Handling Precautions

Advises on environmental conditions, proper handling, and device cleaning protocols.

Product Overview

Key Product Features

Outlines the principal features and characteristics of the pulse oximeter.

Principle of Operation

Applications and Environment

Specifies intended uses, scope of application, and environmental requirements for the device.

Technical Specifications

Main Performance

Details key performance aspects: display types, alarms, and connectivity options.

Measurement Parameters

Defines SpO2 and pulse rate measuring ranges, accuracy, and resolution.

Installation Guide

Front Panel Overview

Identifies and explains controls, indicators, and ports on the device's front panel.

Probe Connection

Provides instructions for correctly connecting the finger probe to the device.

Operating Guide

Included Accessories

Lists all standard accessories provided with the pulse oximeter package.

Application Method

Step-by-step instructions for applying the probe and initiating patient measurement.

Operational Cautions

Important points to observe during device operation for accurate results and safety.

Clinical Restrictions

Identifies patient conditions or factors that may affect measurement accuracy.

Maintenance and Storage

Cleaning and Disinfection

Procedures for maintaining device hygiene using approved cleaning agents.

Device Maintenance

Guidance on battery care, calibration, and general maintenance practices.

Transportation and Storage

Best practices for transporting and storing the device to preserve its condition.

Troubleshooting

Symbol Key

Function Specifications

Appendix 1