    Why the SpO2 pulse rate cannot be displayed normally on my Contec Medical Equipment?
    • D
      Daniel BentleyAug 1, 2025
      If the SpO2 pulse rate isn't displaying normally on your Contec Medical Equipment, it could be due to improper finger positioning. Ensure your finger is correctly placed and try again. If the issue persists, the patient's SpO2 level might be too low for detection. In this case, try again. If you are sure the device works all right, seek a diagnosis from a hospital to check patient’s SpO2 level.
  • G
    garrettlauraAug 8, 2025
    What to do if the SpO2 pulse rate are not displayed stably on my Contec CMS-50E?
    • J
      Jimmy LopezAug 8, 2025
      If the SpO2 pulse rate is not displayed stably on your Contec Medical Equipment, it may be because the finger is not placed deep enough inside the device. Ensure the finger is properly positioned and try again. Another reason could be movement; if the finger is shaking or the patient is moving, ask the patient to keep calm.
  • C
    Christopher LopezAug 16, 2025
    What to do if my Contec CMS-50E device cannot be turned on?
    • K
      Kevin HollandAug 16, 2025
      If your Contec Medical Equipment device won't turn on, the batteries may be drained. Please recharge the battery. Alternatively, the device might be malfunctioning, in which case, please contact the local service center.
  • H
    Hunter RasmussenAug 23, 2025
    Why does the display turn off suddenly on my Contec Medical Equipment?
    • J
      Jordan KelleyAug 23, 2025
      If the display of your Contec Medical Equipment turns off suddenly, it is normal if the device is set to automatically power off within 5 seconds when it cannot detect any signal without an external probe. If not, please recharge the battery.

Summary

Safety

Instructions for Safe Operations

Guidelines for ensuring the device is safe and functional during use and maintenance.

Warnings

Critical safety warnings, including hazardous environments and usage restrictions.

Overview

Principle and Caution

Principle of Measurement

Explanation of how the pulse oximeter measures SpO2 and pulse rate using light.

The Attention of Operation

Important points to consider during the operation of the pulse oximeter for accurate readings.

Clinical Restrictions

Factors and conditions that may affect the accuracy of SpO2 measurements.

Technical Specifications

Operating Guide

Repairing and Maintenance

Troubleshooting

Function Specification

Contec CMS-50E Specifications

General IconGeneral
TypePulse Oximeter
ModelCMS-50E
Measurement ParametersSpO2, PR, PI
SpO2 Range0% - 100%
PR Range30 bpm - 250 bpm
Resolution1%
PR Accuracy±2 bpm or ±2% (whichever is greater)
Operating Temperature5°C to 40°C
DisplayOLED display
SpO2 Accuracy±2% (70%-100%)
Battery Type2 x AAA batteries
Battery Life30 hours
Power ConsumptionLess than 30 mA
Automatic ShutdownYes
Weight50g (including batteries)
Storage Temperature-20°C to 55°C