3 Jumper Setting
28
SIS-8601-LVA
3.6 Power supply select ATX or AT : JP18
JP18 Function
JP18
1 2 3
ATX
JP18
1 2 3
AT (Default)
*Manufactory Default: AT
In the case that the ATX power supply is used,
1. The 5V standby power (5VSB) needs to be supplied from CN3.
2. ON/OFF control signal of ATX power supply (PS-ON) needs to be connect to
CN3.
3. Power switch needs to be connect to CN15(1-3Pin) or CN3(2-3Pin).
4. BIOS Setup
Advanced Chipset Features > Power-Supply Type [ATX]
3.7 Watch Dog Timer output selector: JP13
When the watchdog timer activates, setup involves two jumpers. (CPU processing has
come to a halt), it can reset the system or generate a NMI. This can be setting JP13 as shown
below:
JP13 Function
JP13
1 2 3
NMI (Default)
JP13
1 2 3
Reset
*Manufactory Default: NMI
3.8 LCD Power selector: JP19
JP19
Function
JP19
1 2 3
3.3V(Default)
JP19
1 2 3
5V
*Manufactory Default: 5V