Edition 05/2021 - COMPACT - technical documentation - page 17
SACOME, CONFIDENTIAL Document, it is forbidden to duplicate or communicate this document without previous authorization.
➢ ANNUAL MAINTENANCE
- A kit n° 470892, for the following operation is available for sale.
- Change the pump inlet filter (No. 411861)
- On the boiler:
o Change vaccum valve (No. 408898)
o Change the safety valve (No. 404326)
- On the inlet bloc valves:
o Change the filter (No. 470199)
o Replace the gasket (No. 219100) of 2 non-return valves
o Remove and clean the gasket limiter 12 Bars
o Clean the nucleus of the solenoid inlet water boiler
- On the coffee groups
o Change the O-ring nozzle (No. 403457) and the filter nozzle (No. 403458)
o Clean the 3rd way and the nucleus of the solenoid coffee valves
- On the 2 steam taps
o Change the 2 O-rings (No. 403457)
o Change the 2 gasket (No. 407502)
- On the 2 "steam" output and on the "hot water" output
o Change the O-ring (No. 061200)
o Change the O-ring (No. 055300)
- For water quality issues, it is recommended to completely drain the boiler.