1
W415-0812 / D / 08.16.12
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.
INSTALLATION AND
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone (705)721-1212 • Fax (705)722-6031 • www.continental replaces.com • ask@continental re.on.ca
1.24B
$10.00
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
SAFETY INFORMATION
!
WARNING
- Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbours phone. Follow the gas suppliers
instructions.
If you cannot reach your gas supplier, call the
re department.
- Installation and service must be performed by a
quali ed installer, service agency or the supplier.
If the information in these instructions
are not followed exactly, a re or
explosion may result causing property
damage, personal injury or loss of life.
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
WARNING
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certi ed kit is used.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACES HEATERS.
BCDV40-N
NATURAL GAS
BCDV40-P
PROPANE

Table of Contents

Questions and Answers

  • K
    Kristine ValenciaAug 19, 2025
    Why does the main burner go out but the pilot stays on in my Continental Fireplaces BCDV40-N Indoor Fireplace?
    • G
      gonzalezanthonySep 12, 2025
      If the main burner of your Continental Fireplaces Indoor Fireplace goes out while the pilot stays on, it might be due to several reasons. First, the pilot flame might not be large enough or not engulfing the thermopile, in which case you should turn up the pilot flame. Second, the thermopile connection to the valve may be shorting; try cleaning the connection and reconnecting it. It may also be necessary to replace the pilot assembly or the thermopile/valve.
  • J
    Joseph MontgomeryAug 21, 2025
    Why are the flames too large or too small on my Continental Fireplaces BCDV40-N?
    • O
      obrienjohnAug 21, 2025
      If the flames of your Continental Fireplaces Indoor Fireplace are consistently too large or too small, there could be several causes. You might be out of propane gas, so filling the tank is recommended. Another potential cause is an incorrect spark gap. The spark gap should be 0.150” to 0.175” (5/32” to 11/64” approx.) from the electrode tip and the pilot burner. Also, check that the manual valve is turned on to ensure there is gas at the pilot burner. Finally, the unit might be over-fired or under-fired, so check the pressure readings.
  • M
    Michael BerryAug 23, 2025
    What to do if the main burner and pilot light go out on my Continental Fireplaces Indoor Fireplace?
    • A
      Amanda ScottAug 23, 2025
      If the main burner and pilot light both go out on your Continental Fireplaces Indoor Fireplace, it could be due to a few reasons. The vent might be blocked, so you should check for any blockages. Alternatively, the vent could be re-circulating; in this case, check the joint seals and installation. Also, the flexible vent might have become disconnected from the appliance, so ensure it is re-attached. Finally, ensure that the cap was replaced.
  • M
    Michael JonesAug 26, 2025
    Why do I smell exhaust fumes and get headaches from my Continental Fireplaces BCDV40-N Indoor Fireplace?
    • L
      Lori GutierrezAug 27, 2025
      If you smell exhaust fumes or experience headaches when using your Continental Fireplaces Indoor Fireplace, it indicates that the appliance is spilling. Ensure the exhaust bracket gasket is properly sealed.
  • A
    Angela SandersAug 28, 2025
    Why is carbon depositing on the glass, logs, or combustion chamber of my Continental Fireplaces Indoor Fireplace?
    • T
      Tracy McdonaldAug 28, 2025
      If you notice carbon being deposited on the glass, logs, or combustion chamber surfaces of your Continental Fireplaces Indoor Fireplace, it could be due to a blocked air shutter. Make sure the air shutter opening is free of lint or other obstructions. Additionally, the flame might be impinging on the logs or combustion chamber, so check that the logs are correctly positioned.
  • J
    Jonathan ParksAug 30, 2025
    Why are the flames so aggressive in my Continental Fireplaces BCDV40-N Indoor Fireplace?
    • E
      eduardo60Aug 30, 2025
      If the flames of your Continental Fireplaces Indoor Fireplace are very aggressive, it could be because the door is ajar. Make sure the door is tightly sealed. Another reason could be that the venting action is too great, so check to ensure the venting is properly sealed.
  • C
    chelsea39Sep 2, 2025
    How to fix a pilot light that won't light on my Continental Fireplaces Indoor Fireplace?
    • T
      Tyrone WoodSep 2, 2025
      If the pilot of your Continental Fireplaces Indoor Fireplace will not light, first check if there is a spark at the pilot burner. You can check if the pilot can be lit by a match. Also, check that the wire is connected to the push button igniter and ensure the push button igniter is tightened.
  • L
    Lucas CollinsSep 4, 2025
    What causes the white/grey film forming on my Continental Fireplaces BCDV40-N Indoor Fireplace and how to remove it?
    • N
      Nathaniel SullivanSep 4, 2025
      If a white or grey film forms on your Continental Fireplaces Indoor Fireplace, it is likely due to sulphur from the fuel being deposited on the glass, logs, or combustion chamber surfaces. Clean the glass with a recommended gas appliance glass cleaner.
  • B
    Barbara TorresSep 6, 2025
    Why does my Continental Fireplaces BCDV40-N main burner come on when the remote wall switch is off?
    • C
      Cheryl HooverSep 6, 2025
      If the remote wall switch is in the 'OFF' position and the main burner comes on when the gas knob is turned to the 'ON' position on your Continental Fireplaces Indoor Fireplace, the wall switch is likely mounted upside down. Reverse it.
  • K
    Karen CamposSep 9, 2025
    What happens if the gas piping is undersized for my Continental Fireplaces BCDV40-N Indoor Fireplace?
    • D
      Destiny Fischer MDSep 9, 2025
      If the gas piping is undersized for your Continental Fireplaces Indoor Fireplace, check if the supply piping size is to code and correct all undersized piping.

Continental Fireplaces BCDV40-N Specifications

General IconGeneral
ModelBCDV40-N
CategoryIndoor Fireplace
TypeDirect Vent Gas Fireplace
Fuel TypeNatural Gas
EfficiencyUp to 70%
VentingDirect Vent
IgnitionElectronic Ignition
FinishBlack
BTU Input40, 000 BTU/h
BTU40, 000 BTU/h

Related product manuals