1. Plug sensor head into meter body.
This is a keyed plug.
Line it up, do not use force.
2. Turn unit on by pressing .
3. Load span & mass data or recall previously
loaded data. To load span data simply
hold down SPAN while using UP (Hz/N) or
DOWN (Hz/Lbs) to set the number.
When the correct number appears in
the display window, simply release the
SPAN key. The unit will beep once to
acknowledge acceptance of this setting.
To load mass data simply hold down
MASS while using UP (Hz/N) or DOWN
(Hz/Lbs) to set the number.
When the correct number appears in
the display window, simply release the
MASS key. The unit will beep once to
acknowledge acceptance of this setting.
To save individual entries into memory,
press the appropriate memory key,
or as soon as the SPAN or MASS keys
have been released. The meter will
beep twice to acknowledge the entry
into memory.
To recall stored span and mass data,
simply press
according to where you previously
entered the values.
Power Transmission Products 5.0 Setup & Use Procedure
9
MEM 1
MEM 2
MEM 3
5.0 Setup & Use Procedure
ON/OFF
SPAN
(m)
MASS
(kg/m)
UP
(Hz/N)
SPAN
(m)
DOWN
(Hz/Lbs)
UP
(Hz/N)
+
OR
MASS
(kg/m)
DOWN
(Hz/Lbs)
UP
(Hz/N)
+
OR
MEM 1
MEM 2
MEM 3
,
OR
4. Aim sensor at center of selected belt span. Tap
or pluck the belt. The meter will beep once to
indicate that a measurement was taken.
5. Display window will show frequency results.
6. Press UP (Hz/N) to
toggle results to newtons.
7. Press DOWN (Hz/Lbs) to
toggle results to pounds
ƒ
.
NOTE: Pressing either toggle a second time
will return display to the Hz value.
8. Re-adjust belt tension and repeat
measurement until target tension results
are attained.
UP
(Hz/N)
DOWN
(Hz/Lbs)
97. 4
N
Hz
lbs
0225
N
Hz
lbs
0050
N
Hz
lbs
Gap
3/8 in.
to 2 in.