NOTE !: Always power the motor's hall sensors using the auxilary power supply intrnally generated by the
MiniAx SMPS (Terminal 12 +V).
If an external power supply is used, open solder bridge S11.
WARNING:
Such an external power supply, if used to supply the incremental encoder + hall effect sensors,
must be applied to the motor at the same time the the MiniAx is switched on.
1.8 Power inputs and outputs
+AT (Input). Positive continuous power supply. (allowed range between 20V and 80V).
-AT (Input). Negative Continuous power supply. Internally connected to the Common Zero
Signal GND.
U (Output). Motor connection U phase
V (Output). Motor connection V phase
W (Output). Motor connection W phase