13
TROUBLE SHOOTING
NOT
WORKING
POOR
COOLING
E1
(High Pressure)
E2
(Low Pressure)
E3
(Sensor Problem)
AF
(Anti Freezing)
TROUBLE CHECK REMEDY
Power plug correctly connected Connect plug correctly
POWER button “OFF” Press POWER button to “ON”
Blown fuse in mains plug Replace fuse (MUST BE 13amp.)
Fuse (supply) blown Exchange fuse in board
Breaker on switch board tripped Check load capacity and reset
Ambient temp. too high Use only below 45℃
(HSC-3500 : 40℃)
Filter blocked with dust Clean Filter
Dust in heat exchanger Clean heat exchanger
Obstacle against inlet side Remove and allow 50cm.clearance
Ambient temp. too high Use only below 45℃ (HSC-3500 : 40℃)
Motor outdoor is not operated ●Check the power supply or replace
the motor
(by authorised service personnel only)
Hot air from chamber is not blown Make good condition to blow out
out completely hot air
Refrigerant is leaked. Supply optimum refrigerant and check
Check with manifold gauge the leakage
(by authorised service personnel only)
Thermistor sensor wire is cut Change the thermistor sensor
Evaporator is frozen Operate continuously till “AF”
(Ambient temp. is under 20℃) disappeared or operate in “FAN” mode