When the heater is turned off the room fan will continue to run for a further 8 minutes.
SAFETY FEATURES:
Automatic Pre-purge: Before heater ignition this operation is done to evacuate any remains of gas or
flue products from inside the firebox that could be the cause of a mishap.
Automatic Shut-off: Should the flame extinguish for any reason there is an automatic shut off of the
gas supply.
Over temperature protection: In the event of the room fan failing, blockage of airways or incorrect
gas installation, the gas supply will automatically shut off after 5 minutes aproximate. This is due to
temperature increase and to prevent the appliance from over-heating.
Warning
: This appliance must be installed to comply with AS/NZS 5601.1 codes and
regulations and only by a Coonara authorised technician who is responsible for its correct
operation at the time of installation and final commissioning.