15
S280-77-4
!
SAFETY
FOR LIFE
DIGITAL COMMUNICATIONS
80 Data Port Baud Rate Code
81 Real-Time Digital Communications Port Baud
Rate Code
82 Control Communications Address
83 Real-Time Digital Communications Port Hand-
shake Mode Code
84 Number of Line-Sync Characters
85 Real-Time Communications Port Transmit
Enable Delay
86 Auto Time-Tagged Reset
SECURITY CODES
90 Security Code for Level 1
91 Security Code for Level 2
92 Security Code for Level 3
99 Enter System Security
TIMECURRENT CURVE MODIFIERS
100 Complex TCC1 (ON/OFF) - Phase and
Ground
101 TCC1 Selection - Phase and Ground
102 TCC1 Constant Time Adder - Phase and
Ground
103 TCC1 Multiplier Value - Phase and Ground
104 TCC1 Minimum Response Time - Phase
and Ground
110 Complex TCC2 (ON/OFF) - Phase and
Ground
111 TCC2 Selection - Phase and Ground
112 TCC2 Constant Time Adder - Phase and
Ground
113 TCC2 Multiplier Value - Phase and Ground
114 TCC2 Minimum Response Time - Phase
and Ground
SENSITIVE GROUND/EARTH FAULT
120 Sensitive Ground/Earth Fault (ON/OFF)
121 Percent of Ground Minimum Trip
122 Percent of Alternate Ground Minimum Trip
123 Sensitive Ground/Earth Trip Time
124 Operations to Lockout
125 Sensitive Ground/Earth Fault Status
HIGH-CURRENT TRIP
130 High-Current Trip - Phase (ON/OFF)
131 High-Current Trip - Ground (ON/OFF)
132 High-Current Trip (Multiple of Minimum Trip)-
Phase and Ground
133 High-Current Trip (Trip Time Delay) - Phase
and Ground
134 High-Current Trip (Active Shot Number)- Phase
and Ground
HIGH-CURRENT LOCKOUT
140 High-Current Lockout - Phase (ON/OFF)
141 High-Current Lockout - Ground (ON/OFF)
142 High-Current Lockout (Multiple of Minimum
Trip) - Phase and Ground
143 High-Current Lockout (Active Shot Number)-
Phase and Ground
CLOCK
* 153 Time Clock - Year
* 154 Time Clock - Month and Day
* 155 Time Clock - Hour and Minute
* 156 Time Clock - Second
EVENT RECORDER
160 Number of Events Since Last Reset
161 Event Number
162 Event Type
163 Month and Day
164 Hour and Minute
165 Second
166 Ground Current
167 Phase 1-2 Current
168 Phase 3-4 Current
169 Phase 5-6 Current
DUTY CYCLE MONITOR
* 170 100% Duty Factor
171 Phase 1-2 Duty Cycle
172 Phase 3-4 Duty Cycle
173 Phase 5-6 Duty Cycle
LOAD PROFILE MONITOR
180 Reading Number
181 Time - Hour and Minute
182 Ground Current
183 Phase 1-2 Current
184 Phase 3-4 Current
185 Phase 5-6 Current
SWITCH MODE
190 Active TCC Selection
191 Minimum Target Sensing, Phase and Ground
192 Alternate Minumum Trip Target Sensing,
Phase and Ground
ACCESS ACCESS
CODE PARAMETER CODE PARAMETER
TABLE 1 (contd)
Form 4C Control Standard Access Codes