1-09
Acceleration Time 1 (Tacc1) @
d0.1 to d600 Sec
d10.0
1-10
Deceleration Time 1 (Tdec1) @
d0.1 to d600 Sec
d10.0
d2.0
1-11
Acceleration Time 2 @
d0.1 to d600 Sec
d10.0
1-12
Deceleration Time 2 @
d0.1 to d600 Sec
d10.0
1-13
Jog Acceleration / Deceleration
Time @
d0.1 to d600 Sec
d10.0
d5.0
1-14
Jog Frequency @
d1.0 Hz to d400 Hz
d6.0
1-15
Auto Acceleration / Deceleration
d0: Linear Acceleration/Deceleration
d1: Auto Acceleration, Linear
Deceleration
d2: Linear Acceleration, Auto
Deceleration
d3: Auto Acceleration/Deceleration
d4: Linear Acceleration; Auto
Deceleration, Stall Prevention during
Deceleration
d5: Auto Deceleration; Auto
Acceleration, Stall Prevention during
Deceleration
d0
1-16
S-Curve in Acceleration
d0 to d7
d0
1-17
S-Curve in Deceleration
d0 to d7
d0
1-18
Jog Decelerating Time
d 0.0 Jog Decelerating Time
Determined by Pr.1-13 d 0.1 to d600
d0.0
Group 2 Operation Method Parameters
2-00
Source of Frequency Command
d0: Master Frequency input determined
by digital keypad. (record the
frequency of power loss and it can do
analog overlap plus)
d1: Master Frequency determined by
analog signal DC 0V-10V (external
terminal AVI). (won’t record the
frequency of power loss and it can’t do
analog overlap plus)
d2: Master Frequency determined by
analog signal DC 4mA - 20mA
(external terminal AVI). (won’t record
the frequency of power loss and it can’t
do analog overlap plus)
d3: Master Frequency determined by
Potentiometer on the digital keypad.
d0
d4