33
(won’t record the frequency of power
loss and it can do analog overlap plus)
d4: Master Frequency operated by RS-
485 serial communication interface and
record frequency of power loss. (record
the frequency of power loss and it can
do analog overlap plus)
d5: Master Frequency operated by RS-
485 serial communication interface and
won’t record frequency before power
loss. (won’t record the frequency of
power loss and it can do analog
overlap plus)
2-01
Source of Operation Command
d0: by Digital Keypad
d1: by external terminals, keypad
STOP enabled
d2: by external terminals, keypad
STOP disabled
d3: by RS-485 communication
interface, keypad STOP enabled
d4: by RS-485 communication
interface, keypad STOP disabled
d0
d1
2-02
Stop Method
d0: Ramp Stop d1: Coast Stop
d0
2-03
PWM Carrier Frequency
d3: 3KHz
d4: 4KHz
d5: 5KHz
d6: 6KHz
d7: 7KHz
d8: 8KHz
d9: 9KHz
d10: 10KHz
d10
d5
2-04
Reverse Operation
d0: Enable REV d1: Disable REV
d0
2-05
Loss of ACI Signal
d0: 0 Hz, continue running
d1: Stop the frequency output
d2: Last ACI input command
d0
2-06
Analog Auxiliary Frequency
Operation
d0: Disable
d1: Enable + AVI
d2: Enable + ACI
d0
Group 3 Output Function Parameters
3-00
Analog Output Signal
d0: analog frequency
d1: analog current
d0
3-01
Analog Output Gain @
d1 to d200%
d100
3-02
Desired Freq. Attained
d1.0 to d400 Hz
d1.0
3-03
Terminal Count Value
d0 to d999
d0