EasyManua.ls Logo

Copystar CS-2550 - Maintenance Modes Item List

Copystar CS-2550
282 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2FT-3.0
1-4-2
(2) Maintenance modes item list
Section Item
No.
Content of maintenance item Initial
setting*
General U000 Outputting an own-status report -
U001 Exiting the maintenance mode -
U002 Setting the factory default data -
U003 Setting the service telephone number ***************
U004 Displaying the machine number -
U005 Copying without paper -
U019 Displaying the ROM version -
Initialization U020 Initializing all data -
U021 Initializing memories -
U022 Initializing backup memory -
U026 Evacuation of backup data -
U027 Return of backup data -
Drive, paper
feed, paper
conveying
and cooling
system
U030 Checking motor operation -
U031 Checking switches for paper conveying -
U032 Checking clutch operation
U034 Adjusting the print start timing
Adjusting the leading edge registration
Adjusting the center line
Adjusting the trailing edge margin
4.0/3.6/3.6/3.6/3.6/4.5
-1.0/0.4/-1.2/-1.2/-1.2/0.3
-2.0
U035 Setting folio size
Length
Width
330
210
U051 Adjusting the amount of slack in the paper -10/-15/15/-20/-20/-5
U053 Performing fine adjustment of the motor speed -0.3/0/-0.6/0.5/-0.1/-0.1/
-0.2/-1.3/-1.5/0.6
U055 Setting the motor periodic drive 1/30
U059 Setting the fan mode 5
Optical U060 Adjusting the scanner input properties 12
U061 Turning the exposure lamp on -
U063 Adjusting the shading position 0
U065 Adjusting the scanner magnification
Main scanning direction/auxiliary scanning direction 0/-12
U066 Adjusting the leading edge registration for scanning an
original on the contact glass
10/0
U067 Adjusting the center line for scanning an original on
the contact glass
-4/0
U068 Adjusting the scanning position for originals from the DP 0
U070 Adjusting the DP magnification 0/0
U071 Adjusting the DP scanning timing 0/0/0/0
U072 Adjusting the DP center line 0/0/0
U073 Checking scanner operation -
U074 Adjusting the DP input light luminosity 0
U076 Executing DP automatic adjustment -
U087 Turning the DP scanning position adjust mode on/off ON/35
U089 Outputting a MIP-PG pattern -
U092 Adjusting the scanner automatically -
*Initial setting for executing maintenance item U020

Table of Contents