Maintenance and service
Before starting any maintenance and servicing, the drier must be unpowered.
Remove the plug from the wall socket.
All maintenance of the electrical system must be performed by a qualified electrician.
All maintenance of the cooling system must be performed by a qualified refrigeration
engineer.
Do not use agents/methods to accelerate defrosting or cleaning other than those
recommended by the manufacturer.
Replace the process air filter frequently, preferably before each new job it is installed for, and clean
the drier regularly, as dust and dirt reduce capacity and may cause overheating and fire.
Inspection and cleaning process air filters, water filters and cleaning collection
receptacles
Inspect or clean water filters annually or more frequently if the machine is used in dirty
environments, replace if necessary. Follow the instructions below:
Before starting any maintenance and servicing, the drier must be unpowered.
Remove the plug from the wall socket.