STEP 3: MINIMUM FLAME ADJUSTMENT
WARNING!
These adjustments should be made only for
use of the appliance with natural gas. For
use with liquid propane gas, the choke
screw must be fully turned in a clockwise
direction.
SURFACE BURNERS
1. Light one burner at a time and set the to
the MINIMUM position(small flame).
2. Remove the knob.
3. The range is equipped with a safety valve.
Using a small-size slotted screwdriver,
locate the choke valve on the valve body
and turn the choke screw to the right or left
until the burner flame is adjusted to desired
minimum.
4.
Make sure that the flame does not go
out when
