COSMOS
ALCOHOL
TESTE
R
COSMOS ALCOHOL TESTER TYPE 2000
Installation & Maintenance
INSTRUCTIONS PAGE 04 / 2005-04-02 / TYPE 2000
COMMISSIONING
Your newly delivered machine is already calibrated and ready for use
Check that all the connectors are correctly plugged in (see the cable connections sheet).
Connect the equipment to the mains – the hardware is tested automatically; the numerical display
shows " - - - " and the "Please Wait" panel lights.
According to the room temperature, the rest of the lights will illuminate after approximately 30
seconds and the "Please Wait" light will go out. The equipment is now ready for use.
However, the normal operating temperature of about 34° must be reached before precise readings
can be obtained: this takes about one hour. A 25 Watt electric light bulb provides the heat.
Incidentally
We recommend that, when your COSMOS ALCOHOL TESTER is delivered, your staff place
the machine on a table and run through the functions following the operating instructions. If they
are still unclear about anything, they can always phone us; we are there to help.
Location
The machine's location is crucial to its "success".
Always install it on the way to or near the toilets (but not actually in the facilities)
This ensures that every customer will pass it several times during the evening.
Fixing
The machine is installed using an installation frame. - No special tools are required.
To hang up the machine, unscrew the screws on the back approximately 1 cm, then tighten the
flat nut onto the wooden rear panel. Uncouple the cable connections to the boards (in the door)
and then remove the door so that the casing is easier to install. Then reconnect the cable
connections.
(For connections to the power supply, loudspeaker and coin mechanism see the instructions
on page 5.)
Lastly, don’t forget to screw in the central screw (to prevent theft!!)
Socket
Install a socket above the machine about 2.2 m above the floor or just above the skirting board
(to ensure that the plug cannot be pulled out easily as a joke). We recommend that you use a
switched socket.
Maintenance
This is simple and involves, at most, regularly refilling the machine with straws and recalibrating
it after a certain number of tests (every 6-8 weeks).
Calibration only takes 2-3 minutes and can easily be carried out by any employee – without any
technical knowledge required (see the operating instructions "Calibrating with the gas
calibrator").
Disposal
Because of the COSMOS ALCOHOL TESTER’s durability, this will not be required for several
years, but when it does become necessary, do not throw the battery and the sensor away with the
general rubbish: instead return them to Cosmos and we will dispose of them for you.
COSMOS AUTOMATEN GMBH AM IHLSEE 18 23795 BAD SEGEBERG
Tel: 04551/83838 Fax: 04551/87171