11
ENGLISH
H
L
Changing the oil
1. Switch thegenerator off and let it cool.
2. Remove one of theoil filler caps (9, 12).
3. Open one of theoil drain plugs (10, 11) and let theoil drain out.
Note: The oil could be hot if thegenerator has been used recently.
4. Screw theoil drain plug back in.
5. Add new oil to theengine crankcase (SAE 10W-30).
6. Check theoil level.
7. Screw theoil filler cap back on.
Spark plug maintenance
1. Switch thegenerator off and let it cool.
2. Disconnect thespark plug cap from thespark plug (this is easier if you wiggle it alittle as you pull it).
Note: Do not pull on thecable, hold thespark plug cap.
3. Use thesupplied spark plug wrench to unscrew thespark plug.
4. Clean theelectrodes and check that theelectrode gap is 0.028–0.031 inch (0.7–0.8 mm). Suitable gap
measuring tools are sold separately. Screw thespark plug back into place and reconnect thespark plug cap.
Fuel filter
The fuel tank has afilter fitted to its filler hole. Regular checks should be made to ensure that thefilter is clean
and in good condition. The filter prevents impurities from entering thefuel tank and thefuel system. Always
clean thearea around thefuel filler cap before removing it and make sure that thefuel you use is clean and
contaminant-free.