12
ENGLISH
Troubleshooting guide
The engine will not start.
• The engine switch is set to OFF.
• Check that there is fuel and thefuel cut-off valve is open.
• Is thechoke set to CHOKE?
• Check theoil level. If theoil level is low, theoil level safety cut-off switch
will prevent thegenerator from starting.
• The air filter is clogged.
The engine will run but
the generator will not
produce electricity. Connected
devices will not work.
• The AC on/off switch (17) is set to OFF.
• Make sure that theovervoltage cut-off has not tripped.
• Make sure that thedevices are not faulty, are properly connected to
the generator and that thecables are in good condition.
Disposal
This product should be disposed of in accordance with local regulations.
If you are unsure how to proceed, contact your local authority.
Specifications
Engine Single-cylinder, 4-stroke, OHV
Power 7 hp
Fuel capacity 15 l
Operating time approx. 11 hours
Engine oil SAE 10W-30
Oil capacity 0.6 l
Spark plug F6TC (NGK BP7ES, Bosch WR5DC, Champion N7YC)
Output voltage 230 V, 50 Hz and 12 V
230 V load capacity Running 2600 W, Surge 3000 W
12 V load capacity 8.3 A
Noise level LwA 96 dB(A)
Size 60 × 45 × 46 cm
Weight 42 kg