The temperature increase should be approximately +95°C, and must not exceed 125°C. In
cases where it is hard to access the regeneration flow, the temperature increase alone can
be used to adjust the flow rate. Be aware that the maximum temperature will occur when
outdoor temperatures are highest. If exceptionally high ambient temperatures are expected
(>30°C), the aim should be a temperature increase of less than 95°C. The temperature
increase can be reduced by increasing the regeneration flow rate. If this temperature is too
high, please consult Cotes or your local dealer.
Configuration-C and Configuration-D:
In the Configuration-C and Configuration-D, the dehumidifier is self-adjusting, and adjusts
according to default air flows.