iLEARN System Manual
iLEARN Door Control Menu Screens (continued)
1.4.7 Gate Status Bits #2
01 - Operation Timeout - ‘1’ when Gate Motor times out before Gate reaches Full Open or
Full Closed.
02 - Ready to Operate - ‘1’ when Gate is Ready to Operate.
03 - CTEM Fault - ‘1’ when iDRIVE.G Expansion Module fails to communicate with iDRIVE.G
Controller.
04 - Encoder Fault - ‘1’ when iDRIVE.G reports an error with the iSENSOR.G Encoder.
05 - Open Learned Handshake - ‘1’ indicates iDRIVE.G has “learned” the FULL Open posi-
tion.
06 - Close Learned Handshake - ‘1’ indicates iDRIVE.G has “learned” the FULL CLOSE posi-
tion.
07 - Stop Button - ‘1’ indicates Stop Button present (NC).
08 - Reset Button - ‘1’ indicates Reset Button is pushed.
1.4.8 Gate Command Bits
01 - Gate Slowdown Distance
03 - FSR Close Speed is ON (See Section 4.11)
04 - Hold Closed
05 - Do Not Reset
06 - Learn Open Position
07 - Learn Close Position
08 - Fire Service Hold (FSH)
09 - Fire Service - Phase 2 (FS2)
10 - Fire Service Landing (FSL)
11 - Fire Service Recall (FSR)
12 - Retiring Cam
13 - Buzzer
14 - Slow
15 - Close
16 - Open
1.4.9 Motor Control Bits
03 - Reg Out Test – Factory use. Should be ‘0’ in normal operation.