24
Others
PERFORMANCE DATA SHEET 
|
 P-07FR
• Forpartsandserviceavailability,pleasecontactyourlocaldealerorCoway.
• Thissystemhasbeentestedforthetreatmentofwatercontainingpentavalentarsenic(alsoknowasAs(V),
As(+5),orarsenate)atconcentrationsof0.050mg/Lorless.Thissystemreducespentavalentarsenic,but
maynotremoveotherformsofarsenic.Thissystemistobeusedonwatersuppliescontainingadetectable
freechlorineresidualatthesysteminletoronwatersuppliesthathavebeendemonstratedtocontainonly
pentavalentarsenic.Treatmentwithchloramines(combinedchlorine)isnotsucienttoensurecomplete
conversionoftrivalentarsenictopentavalentarsenic.PleaseseetheArsenicFactssectionofthisPerformance
DataSheetforfurtherinformation.
• Eciencyratingmeansthepercentageoftheinuentwatertothesystemthatisavailabletotheuserasreverse
osmosistreatedwaterunderoperatingconditionsthatapproximatetypicaldailyusage.
• Theproductwatershouldbetestedevery6monthstoensurethatthecontaminantsarebeingreduced
eectively.PleasecontactyourlocaldealerorCowaytoinitiatethisservice.
• Thisreverseosmosissystemcontainsareplaceabletreatmentcomponents,criticalfortheeectivereductionof
totaldissolvedsolidsandthatproductwatershallbetestedperiodicallytoverifythatthesystemisperforming
properly.Replacementofreverseosmosiscomponentshouldbewithoneofidenticalspecications,asdened
bythemanufacturer,toassurethesameeciencyandcontaminantreductionperformance.
• Theestimatedreplacementtimeoflter,whichisaconsumablepart,isnotanindicationofqualityguarantee
period,butitmeanstheidealtimeoflterreplacement.Accordingly,theestimatedtimeoflterreplacement
maybeshortenedincaseitisusedinanareaofpoorwaterquality.v
ModelofFilter Type Usableperiod(months) COSTUS$
WJNF12 NEO-SENSEFILTER 6 48
WJMF12-700 ROMEMBRANEFILTER 24 120
WJIF12 INNO-SENSEFILTER 18 51
ARSENIC FACTS
Arsenic(abbreviatedAs)isfoundnaturallyinsomewellwater.Arsenicinwaterhasnocolor,tasteorodor.Itmust
bemeasuredbyalabtest.Publicwaterutilitiesmusthavetheirwatertestedforarsenic.Youcangettheresults
fromyourwaterutility.Ifyouhaveyourownwell,youcanhavethewatertested.Thelocalhealthdepartment
orthestateenvironmentalhealthagencycanprovidealistofcertiedlabs.Thecostistypically$15to$30.
InformationaboutarsenicinwatercanbefoundontheInternetattheUSEnvironmentalProtectionAgency
website:
www.epa.gov/safewater/arsenic.html
Therearetwoformsofarsenic:pentavalentarsenic(alsocalledAs(V),As(+5),andarsenate)andtrivalentarsenic
(alsocalledAs(III),As(+3),andarsenite).Inwellwater,arsenicmaybepentavalent,trivalent,oracombinationof
both.Specialsamplingproceduresareneededforalabtodeterminewhattypeandhowmuchofeachtypeof
arsenicisinthewater.Checkwiththelabsinyourareatoseeiftheycanprovidethistypeofservice.
Reverseosmosis(RO)watertreatmentsystemsdonotremovetrivalentarsenicfromwaterverywell.ROsystems
areveryeectiveatremovingpentavalentarsenic.Afreechlorineresidualwillrapidlyconverttrivalentarsenic
topentavalentarsenic.Otherwatertreatmentchemicalssuchasozoneandpotassiumpermanganatewillalso
changetrivalentarsenictopentavalentarsenic.Acombinedchlorineresidual(alsocalledchloramine)maynot
convertallthetrivalentarsenic.Ifyougetyourwaterfromapublicwaterutility,contacttheutilitytondoutiffree
chlorineorcombinedchlorineisusedinthewatersystem.
TheP-07FRsystemisdesignedtoremovepentavalentarsenic.Itwillnotconverttrivalentarsenictopentavalent
arsenic.Thesystemwastestedinalab.Underthoseconditions,thesystemreduced0.050mg/Lpentavalent
arsenicto0.010mg/L(ppm)(theUSEPAstandardfordrinkingwater)orless.Theperformanceofthesystemmaybe
dierentatyourinstallation.Havethetreatedwatertestedforarsenictocheckifthesystemisworkingproperly.
TheROcomponentoftheP-07FRsystemmustbereplacedevery24monthstoensurethesystemwillcontinueto
removepentavalentarsenic.Thecomponentidenticationandlocationswhereyoucanpurchasethecomponent
arelistedintheinstallation/operationmanual.
WQA Approved NSF/ANSI 42/53/58 MH  01/24/2011