Water Filtration System Performance Data Sheet
Brand: Neptunus  Model: P-07FR
ThissystemhasbeentestedandcertiedbytheWaterQualityAssociationaccordingtoNSF/ANSI42,53,and58for
thereductionofthesubstanceslistedbelow.Theconcentrationoftheindicatedsubstancesinwaterenteringthe
systemwasreducedtoaconcentrationlessthanorequaltothepermissiblelimitforwaterleavingthesystem,as
speciedinNSF/ANSI42,53,and58.
Substance
Max.Allowable
Concentration
(mg/L)
Average
Inuent
(mg/L)
Average
Euent
(mg/L)
Minimum
Percent
Reduction(%)
Average
Percent
Reduction(%)
Arsenic(Pentavalent) 0.010 0.3512 0.0073 97.2 97.9
Barium 2.0 10.1 0.088 95.7 99.1
Radium226/228 5pCi/L 25pCi/L 5pCi/L N/A N/A
Cadmium 0.005 0.063 0.0016 85.7 97.5
Chromium(Hexavalent) 0.1 0.2945 0.0271 71.2 90.8
Chromium(Trivalent) 0.1 0.3381 0.0017 98.2 99.5
Lead 0.010 0.153 0.005 93.6 95.1
Mercury 0.002 0.00564 0.0004 81.6 93.0
Selenium 0.05 0.1153 0.007 93.9 93.9
TDS <187.5 748.4 69.7 88.8 90.7
AestheticChlorine ≥50%reduction 2.07 0.56 54.53 72.8
VOC* ≥95%reduction 0.3274 0.0008 94.3 99.7
Whiletestingwasperformedunderlaboratoryconditions,actualperformancemayvary.
General Operating Information:
RatedCapacity
270gallons(forVOC)
6600gallons(forAestheticChlorine)
Min-Maxoperatingpressure: 20~120psi(1.4~8.4kgf/cm
2
)
Min-Maxfeedwatertemperature: 41~95ºF(5~35ºC)
RatedServiceFlow
0.07GPM(forVOC)
0.5GPM(forAestheticChlorine)
DailyWaterProductionRate 468GPD
ProductEciencyRating 59.8%
ElectricalRequirements: 120Vac/60Hz
• Donotusewithwaterthatismicrobiologicallyunsafeorofunknownqualitywithoutadequatedisinfection
beforeorafterthesystem.
• Refertotheownersmanualforspecicinstallationinstructions,manufacturer’slimitedwarranty,user
responsibility,andpartsandserviceavailability.
• Theinuentwatertothesystemshallincludethefollowingcharacteristics:
o Noorganicsolvents
o Chlorine:<2ppm
o pH:7-8
o Temperature:41~95ºF(5~35ºC)
o Iron:<2ppm
o Turbidity:<1NTU
o Hardness:<1000mg/L
WQA Approved NSF/ANSI 42/53/58 MH  01/24/2011