94
Record channel: you can select proper channel to record alarm video (Multiple choices).
At the same time, you need to set alarm record in schedule interface (Main Menu Setting
Schedule) and select schedule record in manual record interface (Main Menu
Advance Manual Record).
Latch: Here is for you to set proper delay duration. Value ranges from 10 to 300
seconds. System automatically delays specified seconds in turning off alarm and
activated output after external alarm cancelled.
Tour: Here you can enable tour function when alarm occurs. System supports 1/8-window
tour. Please note the tour setup here has higher priority than the tour setup you set in the
Display interface. Once there two tours are both enabled, system can enable the alarm
tour as you set here when an alarm occurred. If there is no alarm, system implements the
tour setup in the Display interface.
Snapshot: System can snapshot corresponding channel when an alarm occurs. Please
note the activation snapshot has the higher priority than schedule snapshot. If you have
enabled these two types at the same time, system can activate the activation snapshot
when alarm occurs, and otherwise system just operates the schedule snapshot.
Video matrix: Check the box here to enable this function. When an alarm occurs, SPOT
OUT port displays device video output. It displays video (1-window tour) from alarm
activation channel you select at the Record channel item.
Log: Check the box here, system can record local alarm log.
Buzzer: Highlight the icon to enable this function. The buzzer beeps when alarm occurs.
Voice prompts: Check the box here to trigger audio broadcast function. You can select
specified audio file here. System can play the audio file once the corresponding event
occurs.
Please note, network alarm means the alarm signal from the TCP/IP. You can use NET
SDK to activate network alarm. Comparing with the local alarm, there is no type, anti-dither,
alarm upload function.
Please highlight icon to select the corresponding function. After setting all the setups
please click save button, system goes back to the previous menu.