USER MANUAL
14 www.CookingPerformanceGroup.com
after the power supply and gas supply are shut down.
TROUBLESHOOTING
SYMPTOM CAUSES SOLUTIONS
1. Gas pressure is too low.
2. Nozzle is blocked.
3. Connection of the thermocouple is loose.
4. Thermocouple is defective.
5. Gas control valve is malfunctioning.
1. Adjust release valve to get a proper pressure.
2. Unblock nozzle.
3. Tighten thermocouple.
4. Replace thermocouple
5. Replace gas control valve.
burner cannot be ignited
1. Gas pressure is too low.
2. Main burner nozzle is blocked.
3. Gas control valve is defective.
1. Adjust relief valve to get the proper pressure.
2. Unblock nozzle.
3. Replace gas control valve.
1. Diameter of nozzle does not match with the
gas supply.
2. Damper is too large.
3. Gas pressure is too low.
4. F
1. Adjust nozzle diameter.
2. Adjust damper.
3. Adjust relief valve.
Flame is red and accompanied by
black smoke
1. The diameter of the nozzle does not match the
gas supply.
2. Damper is too small.
3. Gas supply has run out.
4. G
demand.
1. Adjust nozzle diameter.
2. Adjust damper.
3. Replace gas.
4. D
demand of the gas.